Sunday, April 19, 2020

Air bottle pressure test

  • Gag the relief valve  
  • Close all openings  
  • Fit test pressure gauge  
  • Remove filling valve and fill F.W completely  
  • Air purge and connect hydraulic pump at filling line.  
  • Apply pressure 1.5 times of working pressure and maintain at least 30 min  
  • Check leaking points.