Hydrophore pump short cycling.

  • Pressure switch faulty- check pressure switch
  • Pressure switch wrongly set
  • Non return valve after pump leaking, hence water under pressure going back to storage tank- that would be indicated by monitoring of the concerned pump if reverse rotation is taking place.
  • Check on/off controller from pump main panel-contacts opening/closing
  • Check if system is overcharged
  • Check if system in undercharged- Since water is incompressible as soon as water is filled up pressure rises but just on little consumption pressure will drop drastically and pump restarts
  • Check for any air leaks
  • Faulty automatic air volume control
  • Not enough water in tank due to clogged pipelines
  • Air  leaking from relief valve
  • Tank is about to empty