- Pressure switch faulty- check pressure switch
- Pressure switch wrongly set
- Non return valve after pump leaking, hence water under pressure going back to storage tank- that would be indicated by monitoring of the concerned pump if reverse rotation is taking place.
- Check on/off controller from pump main panel-contacts opening/closing
- Check if system is overcharged
- Check if system in undercharged- Since water is incompressible as soon as water is filled up pressure rises but just on little consumption pressure will drop drastically and pump restarts
- Check for any air leaks
- Faulty automatic air volume control
- Not enough water in tank due to clogged pipelines
- Air leaking from relief valve
- Tank is about to empty
Marine Engineering exam notes for Seafarers
The information you've provided is quite useful. It's incredibly instructional because it provides some of the most useful information. Thank you for sharing that. water under house Sydney
ReplyDelete