- Gag the relief valve
- Close all openings
- Fit test pressure gauge
- Remove filling valve and fill F.W completely
- Air purge and connect hydraulic pump at filling line.
- Apply pressure 1.5 times of working pressure and maintain at least 30 min
- Check leaking points.