An IC engine of over 200-mm bore or crankcase volume of 0.6 m³ and above, 
shall be provided with crankcase relief door with sufficient relief area.(Regulation) 
Opening pressure = 1/15 bar (0.07 bar) above Atmospheric pressure, but ≯ 3∼7 
bar of explosion pressure. 
Free area of each relief valve ≮ 45 cm². 
Combined area of relief valves ≮ 115 cm² per m³ of crankcase volume.